Educational reference
Methodology
How Power Totals handles formulas, precision, sources, electrical-safety boundaries, privacy, and automated maintenance. The methods, assumptions, sources, and review dates are stated in the page so each figure can be interpreted in context.
How Power Totals handles formulas, precision, sources, electrical-safety boundaries, privacy, and automated maintenance.
How results are calculated
Power Totals uses deterministic arithmetic, explicit units, visible assumptions, and source-backed scientific constants. Values are rounded only for display; calculations retain full JavaScript number precision.
Every interactive result is rendered as ordinary text in the document. Diagrams explain relationships but never replace the numeric result.
Educational use and safety limits
Power Totals provides educational calculations and does not determine electrical-code compliance. It does not size breakers, verify conductor ampacity, select grounding or bonding conductors, calculate code box fill, perform arc-flash analysis, design short-circuit protection, size services, or provide permit advice.
Voltage-drop wire selection searches only for the smallest supported conductor satisfying the user's resistive drop target. It does not verify ampacity, insulation, terminations, overcurrent protection, installation method, or adopted code.
Units and precision
- Exact conversions are used where definitions are exact, including 1 ft = 0.3048 m and 1 in = 25.4 mm.
- AWG diameter and area are computed from the standard mathematical relationship rather than copied from a protected table.
- Material resistance uses visible 20°C resistivity and linear temperature-coefficient assumptions.
- Invalid negatives, invalid zero denominators, non-finite values, and power factors outside 0–1 are rejected.
Source handling
Stable scientific sources and changing publication-status sources are separate. A status watcher may update edition metadata, verification time, a source fingerprint, and a short neutral note. It may never copy protected standard prose or tables, and it may never change calculator logic.
If a status source fails or becomes stale, the site retains the last verified snapshot and replaces “current” wording with a prompt to check the official source. Core tools remain available because their math is independent of code tables.
Privacy and analytics
Calculator arithmetic runs locally, but Power Totals separately collects submitted quote and subscription records. After analytics consent, measurement records include the page, event, interface variant, session identifier, timestamp, referrer URL, and referrer classification; Microsoft Clarity may also process interaction and device information. The Privacy policy explains collection, sharing, cookies, retention, and user choices.
Sponsorship and affiliate separation
Paid sponsors appear in a bordered block labeled “Sponsored.” Sponsorship does not change organic contractor order, directory eligibility, calculator math, permit information, or code content. Sponsor reporting counts campaign impressions and clicks without adding sponsor cookies.
Affiliate products appear only after a completed calculation and only when a checked Renogy or A-iPower product meets the relevant result requirements. Product matching uses approved Impact tracking destinations and does not change the calculator math. If the catalog cannot satisfy a requirement, no product is shown for it. Final compatibility, installation, and purchasing decisions remain with the user and qualified professionals.
Review dates
Formula pages keep their actual review date instead of receiving a new date on every build. A modified date changes only after the explanation or calculation logic changes.